#1592 - 06/07/15 02:16 PM
First FIX for PSU, do on ALL CLONE DM8000HD PSU
|
Japhar Member
Carpal Tunnel
Registered: 10/19/10
Posts: 9993
|
First FIX for PSU, do this on ALL CLONE DM8000HD PSU This needs to be repleaced ALWAYS, as the PSU in the DM8000 goes very high in temperature and YOU MUST replace by best part possible, there is Rubycon 105 degrees as well as 130 degrees, so better part you put longer the PSU will last. Rubycon 1000uF 35V 105 degrees : http://www.ebay.com/itm/400436707192Rubycon 1000uF 35V 130 degrees : http://www.ebay.com/itm/290493007855(Thank you to Toysoft for publishing it)All the best about hardware/support from Johnny_B, link : http://jb8a8f8.comhttp://jb8a8f8.nl
Attachments
PSU.jpg (107 downloads)REPLACE.jpg (1111 downloads)105_degrees.jpg (247 downloads)130_degrees.jpg (1111 downloads)
_________________________
|
Top
|
|
|
|
|
#5336 - 01/22/16 11:51 AM
Re: First FIX for PSU, do on ALL CLONE DM8000HD PSU
[Re: Admin]
|
Japhar Member
Carpal Tunnel
Registered: 10/19/10
Posts: 9993
|
There is 2 PSU Models for the DM8000HD, Model 1 below, 2 first shots. Model 2 below, next/last shot (5L0565). Admin P.S.: Did you checked the capacitors on your clone PSU ? I would change the 2 big 220uF/250V (V1) or 100uF/400V (V2) (depending of your PSU version), 4 large ones (1000uF/35V) and the one small that is 22uF/50V (C109) Model V1 or 47uF/50V Model V2 depending of the version of the PSU (There is 2 versions). All must be minimum 105°, and if possible Rubycon high quality caps. On V2 PSU for DM8000HD you could also have to replace a 47uF 50V capacitor (I put 47uF 63V 105°) near to the 2 big ones (100uF/400v), if the box just loops on the Dreambox LCD logo and never reaches the progress bar (loading image). On V1 PSU for DM8000HD replacing C104 (47uF 25V) by a 47uF 50V get the box the power to have all HDD/DVD/Tuners working. This needs to be replaced if the box stays on the Dream logo at boot or just start booting and then stop and restart booting, going in loop. All four tuners : 5L0565 PSU
Attachments
PSU.jpg (831 downloads)PSU_PCB.jpg (312 downloads)DM8000HD-5L0565-PSU.jpg (858 downloads)
_________________________
|
Top
|
|
|
|
|
#8719 - 06/12/16 04:59 PM
Re: First FIX for PSU, do on ALL CLONE DM8000HD PSU
[Re: Admin]
|
stranger
Registered: 06/08/16
Posts: 3
|
Just about to purchase some capacitors for psu but the big caps you stated are 100uF/400V but on my psu are 220uF/250v (c100 and c101).
Cannot find any caps at 220uF/250v at temp 105c even Rubycon ones are only rated to 85c.
Please clarify.
|
Top
|
|
|
|
|
#8722 - 06/13/16 10:01 AM
Re: First FIX for PSU, do on ALL CLONE DM8000HD PSU
[Re: Admin]
|
Japhar Member
Carpal Tunnel
Registered: 10/21/10
Posts: 2649
|
_________________________
DM8000, DM800se, DM500HD, DM800HD, DM7025, DM7020s, DM7000, DM500s VU+ Solo, VU+ Uno, VU+ Duo, Kathrein UFS910 Tivusat, TNTSat, Fransat, SSR/TSR, BBC1-2-3/ITV DE-OpenBlackHole 1.4 image : http://www.openblackhole.com/
|
Top
|
|
|
|
|
#8729 - 06/13/16 01:39 PM
Re: First FIX for PSU, do on ALL CLONE DM8000HD PSU
[Re: Toysoft]
|
VIPF Japhar
enthusiast
Registered: 03/08/15
Posts: 218
Loc: Netherlands
|
Yeah some psu modifications seems exiting as the use of 100uF/400V instead of 220uF/250V caps.
Which mainly helps to reduce the psu oscillation sound. As for the operation of the psu it makes not really a differences. But if you use a scope you may see a better result, the curve is a bit better. So yes. it's improve the psu a bit, but not really necessary.
But this is my thoughts about it, an other cap believer may think different.
_________________________
Doing nothing leads to nothing. ------------- Please note, for technical support ------------- Will be given here, or on the jb8a8f8 forum and I prefer it in English. Johnny B. Click on the banner if you like to go there..
|
Top
|
|
|
|
|
#8740 - 06/15/16 02:38 PM
Re: First FIX for PSU, do on ALL CLONE DM8000HD PSU
[Re: Admin]
|
stranger
Registered: 06/08/16
Posts: 3
|
Managed to get all caps all Rubycon 105c ones.
Swap them on PSU but no joy, still only blue light on.
Any other suggestions please?
|
Top
|
|
|
|
|
#8766 - 06/17/16 04:44 PM
Re: First FIX for PSU, do on ALL CLONE DM8000HD PSU
[Re: square88]
|
VIPF Japhar
enthusiast
Registered: 03/08/15
Posts: 218
Loc: Netherlands
|
A bit to late response to this, but better late than never they say. I think, check the vdc outputs from the psu, see if there is a failure with one of the outputs. In any case, without having the 3v on the pin 4, the psu will not turn on. More about this, see this topic. https://jb8a8f8.com/support/index.php?threads/testing-the-dm8000hd-psu-without-the-motherboard.84/
_________________________
Doing nothing leads to nothing. ------------- Please note, for technical support ------------- Will be given here, or on the jb8a8f8 forum and I prefer it in English. Johnny B. Click on the banner if you like to go there..
|
Top
|
|
|
|
|
#16692 - 06/20/18 06:50 PM
Re: First FIX for PSU, do on ALL CLONE DM8000HD PSU
[Re: Admin]
|
newbie
Registered: 02/12/17
Posts: 38
Loc: Br/Sp/Interior
|
Ola a todos,os senhores esto afirmando que seria obrigatoriamente a troca dos capacitores das DM8000HD isto faz com teu reiniciamento arranque seja mais rapido mesmo para atual image E qual outras melhorias traz nesta troca antes que eu aplique a nova imagem
modelo 1 abaixo, 2 primeiros disparos j iniciaria perfeitamente
Modelo 2 abaixo, proximo / ultimo tiro (5L0565) ultimo tiro como assim no compreendi este ultimo tiro Ou seria um unico tiro Obrigado
_________________________
Observar !
Ler !
Aprender !
|
Top
|
|
|
|
|
|
|